2024-12-08 03:06:42 +00:00

118 lines
3.7 KiB
JSON

{
"id": "CVE-2023-4777",
"sourceIdentifier": "bugreport@qualys.com",
"published": "2023-09-08T09:15:08.697",
"lastModified": "2024-11-21T08:35:57.827",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nAn incorrect permission check in Qualys Container Scanning Connector Plugin 1.6.2.6 and earlier allows attackers with global Item/Configure permission (while lacking Item/Configure permission on any particular job) to enumerate credentials IDs of credentials stored in Jenkins and to connect to an attacker-specified URL using attacker-specified credentials IDs, capturing credentials stored in Jenkins.\u00a0\n\n"
},
{
"lang": "es",
"value": "Una comprobaci\u00f3n de permisos incorrecta en Qualys Container Scanning Connector Plugin 1.6.2.6 y versiones anteriores permite a los atacantes con autorizaci\u00f3n global Item/Configure (aunque carecen de autorizaci\u00f3n Item/Configure en cualquier job en particular) enumerar los ID de credenciales de las credenciales almacenadas en Jenkins y conectarse a una URL especificada por el atacante, utilizando ID de credenciales especificadas por el atacante, capturando las credenciales almacenadas en Jenkins."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "bugreport@qualys.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 3.1,
"baseSeverity": "LOW",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.6,
"impactScore": 1.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "bugreport@qualys.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:qualys:container_scanning_connector:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.6.2.7",
"matchCriteriaId": "40CC9049-544D-42FD-9494-340ACEAD4BF2"
}
]
}
]
}
],
"references": [
{
"url": "https://www.qualys.com/security-advisories/",
"source": "bugreport@qualys.com",
"tags": [
"Product"
]
},
{
"url": "https://www.qualys.com/security-advisories/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
]
}
]
}