"id": "CVE-2023-51595",
|
|
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
|
|
"published": "2024-05-03T03:16:20.290",
|
|
"lastModified": "2024-11-21T08:38:27.277",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Voltronic Power ViewPower Pro selectDeviceListBy SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the selectDeviceListBy method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of LOCAL SERVICE. Was ZDI-CAN-22163."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Voltronic Power ViewPower Pro selectDeviceListPor vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo por inyecci\u00f3n SQL. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en instalaciones afectadas de Voltronic Power ViewPower Pro. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe dentro del m\u00e9todo selectDeviceListBy. El problema se debe a la falta de validaci\u00f3n adecuada de una cadena proporcionada por el usuario antes de usarla para construir consultas SQL. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de LOCAL SERVICE. Era ZDI-CAN-22163."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "zdi-disclosures@trendmicro.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "zdi-disclosures@trendmicro.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-89"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1897/",
|
|
"source": "zdi-disclosures@trendmicro.com"
|
|
},
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1897/",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108"
|
|
}
|
|
]
|
|
} |