"id": "CVE-2024-12371",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"published": "2024-12-18T16:15:10.907",
"lastModified": "2024-12-18T20:15:21.193",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de apropiaci\u00f3n de dispositivos en Rockwell Automation Power Monitor 1000. Esta vulnerabilidad permite la configuraci\u00f3n de un nuevo usuario titular de la p\u00f3liza sin ninguna autenticaci\u00f3n a trav\u00e9s de API. El usuario titular de la p\u00f3liza es el usuario con m\u00e1s privilegios que puede realizar operaciones de edici\u00f3n, crear usuarios administradores y realizar restablecimientos de f\u00e1brica."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "HIGH",
"vulnerableSystemAvailability": "HIGH",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
]
},
"weaknesses": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html",
"source": "PSIRT@rockwellautomation.com"
}
]
}