René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

371 lines
10 KiB
JSON

{
"id": "CVE-2020-29027",
"sourceIdentifier": "VulnerabilityReporting@secomea.com",
"published": "2021-02-16T16:15:12.973",
"lastModified": "2021-02-18T17:21:20.467",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in GUI of Secomea SiteManager could allow an attacker to cause an XSS Attack. This issue affects: Secomea SiteManager all versions prior to 9.3."
},
{
"lang": "es",
"value": "Una vulnerabilidad de tipo Cross-site Scripting (XSS) en la GUI de Secomea SiteManager, podr\u00eda permitir a un atacante causar un ataque de tipo XSS. Este problema afecta: Secomea SiteManager todas las versiones anteriores a 9.3"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7
},
{
"source": "VulnerabilityReporting@secomea.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "SINGLE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 3.5
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"source": "VulnerabilityReporting@secomea.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_1129_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "9C0FAD6E-F83E-4FCC-974E-234AFF0F6B3B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_1129:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29BFC1D6-82B6-4E20-BBFB-63F33373D78B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_1139_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "8205A78B-7823-4510-A336-317F4913895A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_1139:-:*:*:*:*:*:*:*",
"matchCriteriaId": "856E0FE1-D1FD-47A3-8DE0-A12F6FBD60E8"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_1149_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "B441D7BD-9E88-427D-AF68-55ABE1ECAFFA"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_1149:-:*:*:*:*:*:*:*",
"matchCriteriaId": "060DA5EF-B6FE-4E02-B0A5-EAAF5CF5AC35"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3329_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "6A6940E9-7E5E-4464-A173-5D841C01A372"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3329:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6ABE08F2-C6D0-4CA3-99F4-0654653E7BF3"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3339_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "29745914-FDC8-4409-B86C-CAF455D833BC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3339:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF64F7DA-FD12-4231-B792-EF8F79B587CF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3349_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "69CE2E1A-A1B3-465B-8C49-1CCFF86AD440"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3349:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C7D7926-A5F5-46A1-A6B7-3C99130FA609"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3529_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "A3FCD5A7-19E7-495B-9096-6B176AD2BC32"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3529:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5C5F7D37-729C-4969-9661-C933C9F16980"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3539_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "2CBC771F-EB11-43FC-AC56-AA6BA36BBC61"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3539:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1D26BFEA-056C-4760-8D10-A0DF3677DAD1"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:secomea:sitemanager_3549_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2c",
"matchCriteriaId": "2483D229-EE45-4103-833B-844E34EBB04C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:secomea:sitemanager_3549:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A05A3825-9C8E-43EF-A2DC-F0B06694CCCD"
}
]
}
]
}
],
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3042",
"source": "VulnerabilityReporting@secomea.com",
"tags": [
"Vendor Advisory"
]
}
]
}