"id": "CVE-2022-23449",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2022-04-12T09:15:14.297",
|
|
"lastModified": "2022-04-19T16:09:44.513",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Una vulnerabilidad de DLL Hijacking podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con altos privilegios al colocar una DLL maliciosa en uno de los directorios de la ruta de b\u00fasqueda de DLL"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.3,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.3,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
|
|
"accessVector": "LOCAL",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 6.9
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 3.4,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": true
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-427"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-427"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "7.3",
|
|
"matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "7.3",
|
|
"matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |