René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

120 lines
3.5 KiB
JSON

{
"id": "CVE-2022-34451",
"sourceIdentifier": "security_alert@emc.com",
"published": "2023-02-11T01:23:25.247",
"lastModified": "2023-02-21T15:53:09.487",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "PowerPath Management Appliance with versions 3.3 & 3.2*, 3.1 & 3.0* contains a Stored Cross-site Scripting Vulnerability. An authenticated admin user could potentially exploit this vulnerability, to hijack user sessions or trick a victim application user into unknowingly send arbitrary requests to the server."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7
},
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"source": "security_alert@emc.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "02C04418-5B17-4B1E-A547-88AB9D54437F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.1:*:*:*:*:*:*:*",
"matchCriteriaId": "FC22B1B0-E9A4-44F7-BAA3-7F3F592448FE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.2:*:*:*:*:*:*:*",
"matchCriteriaId": "D92273A9-3C81-4082-9550-DC1497AEDF39"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:3.3:*:*:*:*:*:*:*",
"matchCriteriaId": "8AD7DBFF-1187-4F94-A3A4-95D52E6B3DC4"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/000205404",
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
]
}
]
}