2024-07-14 02:06:08 +00:00

60 lines
2.0 KiB
JSON

{
"id": "CVE-2024-32742",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-05-14T16:17:12.103",
"lastModified": "2024-05-14T19:17:55.627",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CN 4100 (todas las versiones &lt; V3.0). El dispositivo afectado contiene un puerto USB sin restricciones. Un atacante con acceso local al dispositivo podr\u00eda hacer un mal uso del puerto para iniciar otro sistema operativo y obtener acceso completo de lectura/escritura al sistema de archivos."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 0.9,
"impactScore": 6.0
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-1326"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html",
"source": "productcert@siemens.com"
}
]
}