"id": "CVE-2023-1285",
|
|
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"published": "2023-04-14T03:15:07.003",
|
|
"lastModified": "2023-04-24T13:22:28.457",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 5.9,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.2,
|
|
"impactScore": 3.6
|
|
},
|
|
{
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-362"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-364"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:mitsubishielectric:gc-enet-com_firmware:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0A0AA732-9C55-45CA-A049-5D8BC40926A5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:mitsubishielectric:gc-enet-com:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FB5D1352-A15E-43A5-9CF7-374E4DA7A080"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15",
|
|
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
}
|
|
]
|
|
} |