2023-12-22 21:00:28 +00:00

151 lines
4.1 KiB
JSON

{
"id": "CVE-2023-39509",
"sourceIdentifier": "psirt@bosch.com",
"published": "2023-12-18T13:15:07.210",
"lastModified": "2023-12-22T19:45:01.103",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos en las c\u00e1maras IP de Bosch que permite a un usuario autenticado con derechos administrativos ejecutar comandos arbitrarios en el sistema operativo de la c\u00e1mara."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
},
{
"source": "psirt@bosch.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
},
{
"source": "psirt@bosch.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:bosch:cpp13_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.90",
"matchCriteriaId": "76747B70-CBD6-4072-A9C7-EB89017494E9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*",
"matchCriteriaId": "80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:bosch:cpp14_firmware:*:*:*:*:*:*:*:*",
"versionStartIncluding": "8.20",
"versionEndIncluding": "8.81",
"matchCriteriaId": "5233DED6-3919-42BB-ABE0-1907AB33F232"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:bosch:cpp14:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B7872B92-4708-4522-BA8F-5BE941D169AC"
}
]
}
]
}
],
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html",
"source": "psirt@bosch.com",
"tags": [
"Vendor Advisory"
]
}
]
}