René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

211 lines
6.0 KiB
JSON

{
"id": "CVE-2020-11643",
"sourceIdentifier": "cybersecurity@ch.abb.com",
"published": "2020-10-15T15:15:10.953",
"lastModified": "2021-11-04T17:31:05.647",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains."
},
{
"lang": "es",
"value": "Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en B&amp;R GateManager 4260 y 9250 versiones anteriores a 9.0.20262 y GateManager 8250 versiones anteriores a 9.2.620236042, permite a usuarios autenticados visualizar informaci\u00f3n de dispositivos que pertenecen a dominios externos"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
},
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-532"
}
]
},
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-532"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:br-automation:gatemanager_9250_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.0.20262",
"matchCriteriaId": "CA294ABA-2C18-4EC7-95B2-E0BC4EAA4D5C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:br-automation:gatemanager_9250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0B280165-5A6D-481E-A491-D16749CD45FA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:br-automation:gatemanager_4260_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.0.20262",
"matchCriteriaId": "72CD9ABC-BCA3-453D-A26F-3C61237C9C1C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:br-automation:gatemanager_4260:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58B4D4A1-54AB-4849-A1F5-3CDB42FF0712"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:br-automation:gatemanager_8250_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "9.2.620236042",
"matchCriteriaId": "06AB955E-3951-4B3E-8B9D-E5A987FDFBCE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:br-automation:gatemanager_8250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBA1D46A-4C8F-4A1B-8708-A8F488287643"
}
]
}
]
}
],
"references": [
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03",
"source": "cybersecurity@ch.abb.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf",
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
]
}
]
}