mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
143 lines
4.3 KiB
JSON
143 lines
4.3 KiB
JSON
{
|
|
"id": "CVE-2020-14965",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-06-23T14:15:12.823",
|
|
"lastModified": "2021-07-21T11:39:23.747",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "On TP-Link TL-WR740N v4 and TL-WR740ND v4 devices, an attacker with access to the admin panel can inject HTML code and change the HTML context of the target pages and stations in the access-control settings via targets_lists_name or hosts_lists_name. The vulnerability can also be exploited through a CSRF, requiring no authentication as an administrator."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "En los dispositivos TP-Link TL-WR740N versi\u00f3n v4 y TL-WR740ND versi\u00f3n v4, un atacante con acceso al panel de administraci\u00f3n puede inyectar c\u00f3digo HTML y cambiar el contexto HTML de las p\u00e1ginas y estaciones de destino en la configuraci\u00f3n de control de acceso por medio de Target_lists_name o hosts_lists_name. La vulnerabilidad tambi\u00e9n puede ser explotada por medio de un ataque de tipo CSRF, que no requiere autenticaci\u00f3n como administrador"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.8,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.7,
|
|
"impactScore": 2.7
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 3.5
|
|
},
|
|
"baseSeverity": "LOW",
|
|
"exploitabilityScore": 6.8,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": true
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:tp-link:tl-wr740n_firmware:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "13CA99B0-BE20-4850-9D5E-2CC6020C4775"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:tp-link:tl-wr740n:4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "63B5C5A3-E777-4BEA-96AF-914C49E6010E"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:tp-link:tl-wr740nd_firmware:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "FC328D98-029C-4754-8763-1FECC6E857AE"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:tp-link:tl-wr740nd:4.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F04E05E9-01DE-447E-9A7F-B66756B817B6"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://github.com/g-rubert/CVE-2020-14965",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |