mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-29 01:31:20 +00:00
267 lines
7.4 KiB
JSON
267 lines
7.4 KiB
JSON
{
|
|
"id": "CVE-2020-7499",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2020-06-16T20:15:14.770",
|
|
"lastModified": "2022-02-03T14:25:52.640",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una CWE-863: Se presenta una vulnerabilidad de autorizaci\u00f3n incorrecta en U.motion Servers and Touch Panels (versiones afectadas listadas en la notificaci\u00f3n de seguridad) que podr\u00edan causar un acceso no autorizado cuando un usuario poco privilegiado realiza cambios no autorizados"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-863"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-863"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6501-0001_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "B0B3DF18-FE18-4465-8223-8AF2B286746D"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6501-0001:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "22E79A6F-C946-43A7-B492-7F3F8CFB18CC"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6501-0002_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "CF40C8EB-9735-43D5-A947-087EFE6AF6F8"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6501-0002:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4B17C76A-749C-44DA-8144-51E4328C4768"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0410_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "AB0811DB-2E4D-4A14-8F87-2C24189D352A"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0410:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7D91BDED-9BCF-473A-AB1B-824AA1EDE586"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0415_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "E369B5A4-1F69-48C1-8C07-0E7C61683EDA"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0415:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "436B2EB8-6D93-41FF-BD6E-932D69C4E197"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0310_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "0176D45B-9007-4558-8D72-B56454EB9733"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0310:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F046097B-B818-4775-A53D-B22F258CB255"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:mtn6260-0315_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.4.2",
|
|
"matchCriteriaId": "FD29EA41-FA54-45A7-BB61-76D6B1CEF5C4"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:mtn6260-0315:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9DD21D34-FBBD-4645-8C60-42825281D0FE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-133-03/",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |