"id": "CVE-2022-23129",
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"published": "2022-01-21T19:15:10.037",
"lastModified": "2022-01-27T20:09:11.953",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information."
},
{
"lang": "es",
"value": "Una vulnerabilidad de almacenamiento de texto plano de una contrase\u00f1a en Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores y en ICONICS GENESIS64 versiones 10.90 a 10.97, permite a un atacante local autenticado conseguir informaci\u00f3n de autenticaci\u00f3n y acceder a la base de datos de forma ilegal. Esto es debido a que cuando la informaci\u00f3n de configuraci\u00f3n de GridWorX, una funci\u00f3n de enlace de bases de datos de GENESIS64 y MC Works64, es exportada a un archivo CSV, la informaci\u00f3n de autenticaci\u00f3n es guardada en texto plano, y un atacante que pueda acceder a este archivo CSV puede conseguir la informaci\u00f3n de autenticaci\u00f3n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1
},
"baseSeverity": "LOW",
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-312"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*",
"versionStartIncluding": "10.90",
"versionEndIncluding": "10.97",
"matchCriteriaId": "244286B8-A94E-451A-A79F-895B01BCE0FB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.95.210.01",
"matchCriteriaId": "D31E1BFD-8194-4BA1-998B-BC4005454C15"
}
]
}
]
}
],
"references": [
{
"url": "https://jvn.jp/vu/JVNVU95403720/index.html",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Mitigation",
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource",
"VDB Entry"
]
},
{
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf",
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"tags": [
"Mitigation",
"Vendor Advisory"
]
}
]
}