"id": "CVE-2020-10051",
"sourceIdentifier": "productcert@siemens.com",
"published": "2020-09-09T19:15:18.587",
"lastModified": "2020-09-14T19:09:47.863",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC RTLS Locating Manager (todas las versiones anteriores a V2.10.2).&#xa0;Se ejecutan varios servicios de la aplicaci\u00f3n afectada con privilegios SYSTEM, mientras que la ruta de la llamada no es citada.&#xa0;Esto podr\u00eda permitir a un atacante local inyectar comandos arbitrarios que son ejecutados en lugar del servicio leg\u00edtimo."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2
},
"baseSeverity": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-428"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-428"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.10.2",
"matchCriteriaId": "FB5582A7-B6F3-4A5D-AC0E-C278D351F2B9"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}