René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

118 lines
4.2 KiB
JSON

{
"id": "CVE-2013-2796",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2013-08-09T23:55:02.537",
"lastModified": "2013-08-12T20:21:04.173",
"vulnStatus": "Analyzed",
"evaluatorComment": "Per: http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\n\n\"This vulnerability is not exploitable remotely.\"",
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
},
{
"lang": "es",
"value": "Schneider Electric Vijeo Citect v7.20 y anteriores, CitectSCADA v7.20 y anteriores, y PowerLogic SCADA v7.20 y anteriores, permite a atacantes remotos leer ficheros, enviar peticiones HTTP a servidores intranet, o causar una denegaci\u00f3n del servicio (consumo de CPU y memoria) a trav\u00e9s de fichero XML que contiene una declaraci\u00f3n de entidad externa, junto con una referencia de entidad, en relaci\u00f3n con un fallo en XML External Entity (XXE)."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"accessVector": "LOCAL",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.4,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*",
"versionEndIncluding": "7.20",
"matchCriteriaId": "3F38EF72-DCCB-47DE-AF76-73A78D9F069A"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:citectscada:7.10:*:*:*:*:*:*:*",
"matchCriteriaId": "E87F308E-8874-40CD-BB46-9CD955AEE26E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*",
"versionEndIncluding": "7.20",
"matchCriteriaId": "692487FE-D5CC-4289-8C4B-26C30C12BB08"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.10:*:*:*:*:*:*:*",
"matchCriteriaId": "227FA3FF-F09B-4891-9B90-37563E1A579C"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:vijeo_citect:*:*:*:*:*:*:*:*",
"versionEndIncluding": "7.20",
"matchCriteriaId": "261173CE-D744-4427-ABCB-AD9BA9CCCF25"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:vijeo_citect:7.10:*:*:*:*:*:*:*",
"matchCriteriaId": "281F678E-1B21-4EFD-A9F6-016FCECF1DA0"
}
]
}
]
}
],
"references": [
{
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
]
},
{
"url": "http://www.citect.schneider-electric.com/cs-HF720SP459363",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch"
]
}
]
}