2023-05-16 16:11:11 +02:00

155 lines
5.3 KiB
JSON

{
"id": "CVE-2023-1617",
"sourceIdentifier": "cybersecurity@ch.abb.com",
"published": "2023-04-14T12:15:07.377",
"lastModified": "2023-04-24T13:21:35.890",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules).\u00a0 This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization.\nThis issue affects B&R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9.\n\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.96.8",
"matchCriteriaId": "C94CCB17-792C-4B9E-9EB2-5AC0888CF3DB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.0.0",
"versionEndIncluding": "4.06.4",
"matchCriteriaId": "96C5BD56-2064-4219-970C-8AEDA8F85D20"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.10.0",
"versionEndIncluding": "4.16.3",
"matchCriteriaId": "EF05318D-11E2-40D4-9556-8A83D0B6ABEB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.20.0",
"versionEndIncluding": "4.26.8",
"matchCriteriaId": "115D84EC-19BD-4CAD-9BAD-6FE9A56E14A1"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.30.0",
"versionEndExcluding": "4.34.7",
"matchCriteriaId": "B28066C3-3BF0-4D87-B847-7DA3F126E39F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.40.0",
"versionEndIncluding": "4.45.1",
"matchCriteriaId": "7C048F8F-7D8F-4CC3-91F9-631A3F96A533"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.50.0",
"versionEndIncluding": "4.53.0",
"matchCriteriaId": "A56A6BDA-4BC1-4D06-98F2-8CE089F07E3D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.70.0",
"versionEndExcluding": "4.73.0",
"matchCriteriaId": "2E56F00F-57F9-407E-92A4-E03CDD074522"
}
]
}
]
}
],
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1681046878970-en-original-1.0.pdf",
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
]
}
]
}