2024-08-13 10:03:13 +00:00

108 lines
4.8 KiB
JSON

{
"id": "CVE-2024-26277",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-04-09T09:15:24.670",
"lastModified": "2024-08-13T08:15:10.003",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V2312.0004), Parasolid V35.1 (Todas las versiones &lt; V35.1.254), Parasolid V36.0 (Todas las versiones &lt; V36.0.207), Parasolid V36.1 (Todas las versiones &lt; V36.1.147), Teamcenter Visualization V14.2 (todas las versiones), Teamcenter Visualization V14.3 (todas las versiones &lt; V14.3.0.9), Teamcenter Visualization V2312 (todas las versiones &lt; V2312.0004). Las aplicaciones afectadas contienen una vulnerabilidad de desreferencia de puntero nulo al analizar archivos X_T especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para bloquear la aplicaci\u00f3n y provocar una condici\u00f3n de denegaci\u00f3n de servicio."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "PASSIVE",
"vulnerableSystemConfidentiality": "NONE",
"vulnerableSystemIntegrity": "NONE",
"vulnerableSystemAvailability": "LOW",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"subsequentSystemAvailability": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirements": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"automatable": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
}
}
],
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222019.html",
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html",
"source": "productcert@siemens.com"
}
]
}