2024-07-14 02:06:08 +00:00

97 lines
3.5 KiB
JSON

{
"id": "CVE-2024-4235",
"sourceIdentifier": "cna@vuldb.com",
"published": "2024-04-26T18:15:46.527",
"lastModified": "2024-06-04T19:20:32.857",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Netgear DG834Gv5 1.6.01.34. This vulnerability affects unknown code of the component Web Management Interface. The manipulation leads to cleartext storage of sensitive information. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-262126 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Netgear DG834Gv5 1.6.01.34 y clasificada como problem\u00e1tica. Esta vulnerabilidad afecta a c\u00f3digo desconocido del componente Web Management Interface. La manipulaci\u00f3n conduce al almacenamiento en texto plano de informaci\u00f3n confidencial. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-262126 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4
}
],
"cvssMetricV2": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "MULTIPLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.3
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.4,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "cna@vuldb.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-312"
}
]
}
],
"references": [
{
"url": "https://netsecfish.notion.site/Netgear-DG834Gv5-Plain-Text-Credentials-Exposure-22e94fe066014490bebd349775d10b27?pvs=4",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.262126",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.262126",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.319148",
"source": "cna@vuldb.com"
}
]
}