mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
97 lines
3.3 KiB
JSON
97 lines
3.3 KiB
JSON
{
|
|
"id": "CVE-2024-4240",
|
|
"sourceIdentifier": "cna@vuldb.com",
|
|
"published": "2024-04-26T21:15:50.280",
|
|
"lastModified": "2024-06-04T19:20:33.263",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se encontr\u00f3 una vulnerabilidad en Tenda W9 1.0.0.7(4456). Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formQosManageDouble_user. La manipulaci\u00f3n del argumento ssidIndex provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El identificador asociado de esta vulnerabilidad es VDB-262131. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cna@vuldb.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "cna@vuldb.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 9.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cna@vuldb.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_auto.md",
|
|
"source": "cna@vuldb.com"
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?ctiid.262131",
|
|
"source": "cna@vuldb.com"
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?id.262131",
|
|
"source": "cna@vuldb.com"
|
|
},
|
|
{
|
|
"url": "https://vuldb.com/?submit.319822",
|
|
"source": "cna@vuldb.com"
|
|
}
|
|
]
|
|
} |