2024-07-14 02:06:08 +00:00

97 lines
3.5 KiB
JSON

{
"id": "CVE-2024-4243",
"sourceIdentifier": "cna@vuldb.com",
"published": "2024-04-26T22:15:08.640",
"lastModified": "2024-06-04T19:20:33.497",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido encontrada en Tenda W9 1.0.0.7(4456) y clasificada como cr\u00edtica. La funci\u00f3n formwrlSSIDset del fichero /goform/wifiSSIDset es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento ssidIndex provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-262134 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "cna@vuldb.com",
"type": "Secondary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "cna@vuldb.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formwrlSSIDset.md",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.262134",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.262134",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.319825",
"source": "cna@vuldb.com"
}
]
}