"id": "CVE-2024-45824",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2024-09-12T14:16:06.953",
|
|
"lastModified": "2024-09-12T18:14:03.913",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CVE-2024-45824 IMPACT\n\n\n\nA remote\ncode vulnerability exists in the affected products. The vulnerability occurs\nwhen chained with Path Traversal, Command Injection, and XSS Vulnerabilities\nand allows for full unauthenticated remote code execution. The link in the\nmitigations section below contains patches to fix this issue."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CVE-2024-45824 IMPACTO Existe una vulnerabilidad de c\u00f3digo remoto en los productos afectados. La vulnerabilidad se produce cuando se combina con vulnerabilidades de path traversal, inyecci\u00f3n de comandos y XSS y permite la ejecuci\u00f3n de c\u00f3digo remoto sin autenticaci\u00f3n. El enlace en la secci\u00f3n de mitigaciones a continuaci\u00f3n contiene parches para solucionar este problema."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "PRESENT",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnerableSystemConfidentiality": "HIGH",
|
|
"vulnerableSystemIntegrity": "HIGH",
|
|
"vulnerableSystemAvailability": "HIGH",
|
|
"subsequentSystemConfidentiality": "NONE",
|
|
"subsequentSystemIntegrity": "NONE",
|
|
"subsequentSystemAvailability": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirements": "NOT_DEFINED",
|
|
"integrityRequirements": "NOT_DEFINED",
|
|
"availabilityRequirements": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
|
|
"safety": "NOT_DEFINED",
|
|
"automatable": "NOT_DEFINED",
|
|
"recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"baseScore": 9.2,
|
|
"baseSeverity": "CRITICAL"
|
|
}
|
|
}
|
|
],
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-77"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1696.html",
|
|
"source": "PSIRT@rockwellautomation.com"
|
|
}
|
|
]
|
|
} |