"id": "CVE-2024-5961",
|
|
"sourceIdentifier": "cvd@cert.pl",
|
|
"published": "2024-06-14T08:15:42.377",
|
|
"lastModified": "2024-06-17T12:42:04.623",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Improper neutralization of input during web page generation vulnerability in 2ClickPortal software allows reflected cross-site scripting\u00a0(XSS).\u00a0An attacker might trick somebody into using a crafted URL, which will cause a script to be run in user's browser.\u00a0This issue affects 2ClickPortal software versions from 7.2.31 through 7.6.4."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "La neutralizaci\u00f3n inadecuada de la entrada durante la vulnerabilidad de generaci\u00f3n de p\u00e1ginas web en el software 2ClickPortal permite cross-site scripting (XSS) reflejado. Un atacante podr\u00eda enga\u00f1ar a alguien para que utilice una URL manipulada, lo que provocar\u00e1 que se ejecute un script en el navegador del usuario. Este problema afecta a las versiones del software 2ClickPortal desde la 7.2.31 hasta la 7.6.4."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "cvd@cert.pl",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:A/V:X/RE:X/U:Clear",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "PASSIVE",
|
|
"vulnerableSystemConfidentiality": "LOW",
|
|
"vulnerableSystemIntegrity": "LOW",
|
|
"vulnerableSystemAvailability": "LOW",
|
|
"subsequentSystemConfidentiality": "LOW",
|
|
"subsequentSystemIntegrity": "LOW",
|
|
"subsequentSystemAvailability": "LOW",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirements": "NOT_DEFINED",
|
|
"integrityRequirements": "NOT_DEFINED",
|
|
"availabilityRequirements": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
|
|
"safety": "NOT_DEFINED",
|
|
"automatable": "YES",
|
|
"recovery": "AUTOMATIC",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "CLEAR",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cvd@cert.pl",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://2clickportal.pl/",
|
|
"source": "cvd@cert.pl"
|
|
},
|
|
{
|
|
"url": "https://cert.pl/en/posts/2024/06/CVE-2024-5961/",
|
|
"source": "cvd@cert.pl"
|
|
},
|
|
{
|
|
"url": "https://cert.pl/posts/2024/06/CVE-2024-5961/",
|
|
"source": "cvd@cert.pl"
|
|
}
|
|
]
|
|
} |