2023-12-19 19:00:28 +00:00

127 lines
4.0 KiB
JSON

{
"id": "CVE-2023-46713",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2023-12-13T07:15:24.547",
"lastModified": "2023-12-19T18:59:02.837",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An improper output neutralization for logs in Fortinet FortiWeb 6.2.0 - 6.2.8, 6.3.0 - 6.3.23, 7.0.0 - 7.0.9, 7.2.0 - 7.2.5 and 7.4.0 may allow an attacker to forge traffic logs via a crafted URL of the web application."
},
{
"lang": "es",
"value": "Una neutralizaci\u00f3n de salida inadecuada para los registros en Fortinet FortiWeb 6.2.0 - 6.2.8, 6.3.0 - 6.3.23, 7.0.0 - 7.0.9, 7.2.0 - 7.2.5 y 7.4.0 puede permitir que un atacante falsifique registros de tr\u00e1fico a trav\u00e9s de una URL manipulada de la aplicaci\u00f3n web."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "psirt@fortinet.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-117"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.2.0",
"versionEndIncluding": "6.2.8",
"matchCriteriaId": "B780406C-A6CC-40A8-BB80-2BFBC0E39F7D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.3.0",
"versionEndIncluding": "6.3.23",
"matchCriteriaId": "29BAA789-62A7-4040-B6F7-8E70FFBA0399"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.0.0",
"versionEndIncluding": "7.0.9",
"matchCriteriaId": "BE91BE98-9518-48C1-8063-5F6A8AE50A73"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.2.0",
"versionEndIncluding": "7.2.5",
"matchCriteriaId": "7700D448-6A28-4033-9383-B42FA04DCBFB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiweb:7.4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A5E0DF8E-3272-4302-A1A0-F7981E383E47"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.com/psirt/FG-IR-23-256",
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
]
}
]
}