"id": "CVE-2022-46823",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-01-10T12:15:23.753",
|
|
"lastModified": "2023-01-13T16:11:55.400",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.4), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.0 < V3.3.9), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.1,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 2.7
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 9.3,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.8
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-79"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2.3.0",
|
|
"versionEndExcluding": "2.3.4",
|
|
"matchCriteriaId": "FA388A2C-406A-4911-96EC-ACB1574B83AC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "3.3.0",
|
|
"versionEndExcluding": "3.3.9",
|
|
"matchCriteriaId": "506D83D7-350A-4586-83AE-93E56C61C5FE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496604.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |