2024-07-14 02:06:08 +00:00

157 lines
5.4 KiB
JSON

{
"id": "CVE-2021-35533",
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"published": "2021-11-26T17:15:07.743",
"lastModified": "2023-05-16T21:04:23.433",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions)."
},
{
"lang": "es",
"value": "Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en el analizador de APDU en la funci\u00f3n IEC 60870-5-104 de la interfaz de comunicaci\u00f3n bidireccional (BCI) de la serie RTU500 de Hitachi Energy permite a un atacante causar el reinicio de la CMU RTU500 receptora en la que est\u00e1 habilitado el BCI cuando recibe un mensaje especialmente dise\u00f1ado. Por defecto, la funci\u00f3n BCI IEC 60870-5-104 est\u00e1 deshabilitada (no configurada). Este problema afecta a: Firmware de la CMU de la serie Hitachi Energy RTU500, versi\u00f3n 12.0.* (todas las versiones); Firmware de la CMU, versi\u00f3n 12.2.* (todas las versiones); Firmware de la CMU, versi\u00f3n 12.4.* (todas las versiones)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.1
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.6,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE94252D-03EE-451B-8322-B4DBC790C6E9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:12.0:*:*:*:*:*:*:*",
"matchCriteriaId": "9BA3F33A-8787-4128-A790-685BCB272A82"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:12.2:*:*:*:*:*:*:*",
"matchCriteriaId": "FCD4343D-4B6E-4D6A-A2F3-EFA5CFE4290D"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:hitachienergy:rtu500_firmware:12.4:*:*:*:*:*:*:*",
"matchCriteriaId": "9CCC7155-16F2-4E60-ABCB-0E6FF71CEC67"
}
]
}
]
}
],
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063&LanguageCode=en&DocumentPartId=&Action=Launch",
"source": "cybersecurity@hitachienergy.com",
"tags": [
"Vendor Advisory"
]
}
]
}