"id": "CVE-2023-38532",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-08-08T10:15:16.403",
"lastModified": "2023-12-22T15:16:50.043",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 4.7
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-770"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-770"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "34.1",
"versionEndExcluding": "34.1.258",
"matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.0",
"versionEndExcluding": "35.0.254",
"matchCriteriaId": "0B5F1A02-44EB-45AA-B071-764B64473313"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.1",
"versionEndExcluding": "35.1.171",
"matchCriteriaId": "EA7FF725-2396-492A-8B97-CA77B4EFCC48"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.1",
"versionEndExcluding": "14.1.0.11",
"matchCriteriaId": "9EF3388B-D057-4DB9-96AE-B6F4678FE5B8"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.2",
"versionEndExcluding": "14.2.0.6",
"matchCriteriaId": "7E1EFF45-5311-4E89-B736-271EF3C0C232"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionStartIncluding": "14.3",
"versionEndExcluding": "14.3.0.3",
"matchCriteriaId": "99F0D457-7D65-40DC-BCFA-339FA5648709"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-407785.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}