René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

130 lines
3.9 KiB
JSON

{
"id": "CVE-2021-22128",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2021-03-04T18:15:13.130",
"lastModified": "2022-07-12T17:42:04.277",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An improper access control vulnerability in FortiProxy SSL VPN portal 2.0.0, 1.2.9 and below versions may allow an authenticated, remote attacker to access internal service such as the ZebOS Shell on the FortiProxy appliance through the Quick Connection functionality."
},
{
"lang": "es",
"value": "Una vulnerabilidad de control de acceso inapropiado en el portal FortiProxy SSL VPN versiones 2.0.0, 1.2.9 y anteriores, puede permitir a un atacante remoto autenticado acceder a servicios internos como ZebOS Shell en el dispositivo FortiProxy por medio de la funcionalidad Quick Connection"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.2.9",
"matchCriteriaId": "204BD02A-F191-4760-8541-8C95E161C364"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiproxy:2.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "F3DD97EA-92AD-4EB1-B731-261F40BFC4BB"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.com/advisory/FG-IR-20-235",
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
]
}
]
}