mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 01:02:25 +00:00
120 lines
4.0 KiB
JSON
120 lines
4.0 KiB
JSON
{
|
|
"id": "CVE-2021-33711",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2021-07-13T11:15:09.900",
|
|
"lastModified": "2021-07-20T19:16:20.410",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). The affected application allows verbose error messages which allow leaking of sensitive information, such as full paths."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en Teamcenter Active Workspace versiones V4 (Todas las versiones anteriores a V4.3.9), Teamcenter Active Workspace versiones V5.0 (Todas las versiones anteriores a V5.0.7), Teamcenter Active Workspace versiones V5.1 (Todas las versiones anteriores a V5.1.4). La aplicaci\u00f3n afectada permite mensajes de error verboso que permiten el filtrado de informaci\u00f3n confidencial, tal y como rutas completas"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 1.4
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-209"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "4.0.0",
|
|
"versionEndExcluding": "4.3.9",
|
|
"matchCriteriaId": "E2BB7B04-DD2F-42A8-89ED-0A014C768061"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "5.0.0",
|
|
"versionEndExcluding": "5.0.7",
|
|
"matchCriteriaId": "3752E0F7-4A3C-411B-9469-443D8C815629"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "5.1.0",
|
|
"versionEndExcluding": "5.1.4",
|
|
"matchCriteriaId": "4785E6FA-C094-49FD-BF8E-6E41EFF14467"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |