"id": "CVE-2021-34306",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2021-07-13T11:15:11.363",
|
|
"lastModified": "2022-10-07T20:47:54.337",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13342)"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2). La biblioteca BMP_Loader.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando se analizan los archivos BMP. Esto podr\u00eda resultar en una condici\u00f3n de corrupci\u00f3n de memoria. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-13342)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 6.8
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.6,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": true
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "13.2.0",
|
|
"matchCriteriaId": "CAFFF33E-9758-4C92-B2BF-2CF0E2EA6217"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "13.2.0",
|
|
"matchCriteriaId": "6C391214-6E11-4196-BF69-5327069864D8"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-835/",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
}
|
|
]
|
|
} |