"id": "CVE-2021-37165",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-08-02T11:15:11.483",
"lastModified": "2021-08-10T16:46:11.037",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead to remote code execution."
},
{
"lang": "es",
"value": "Se ha detectado un problema de desbordamiento del b\u00fafer en el panel de control HMI3 del panel Nexus de Swisslog Healthcare que funciona con versiones de software anteriores a 7.2.5.7 del software Nexus. Cuando es enviado un mensaje al socket TCP de HMI, \u00e9ste es reenviado a la funci\u00f3n hmiProcessMsg mediante el pendingQ, y puede conllevar a una ejecuci\u00f3n de c\u00f3digo remota"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:swisslog-healthcare:hmi-3_control_panel_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.2.5.7",
"matchCriteriaId": "B9286DC1-0111-49C4-9BD4-1601AAD025A9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:swisslog-healthcare:hmi-3_control_panel:-:*:*:*:*:*:*:*",
"matchCriteriaId": "92F48887-6E68-4A96-87F6-C8DB7773C4A2"
}
]
}
]
}
],
"references": [
{
"url": "https://www.armis.com/PwnedPiper",
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.swisslog-healthcare.com",
"source": "cve@mitre.org",
"tags": [
"Product"
]
},
{
"url": "https://www.swisslog-healthcare.com/en-us/customer-care/security-information/cve-disclosures#:~:text=CVE%20Disclosures%20%20%20%20Vulnerability%20Name%20,%20%20CVE-2021-37164%20%204%20more%20rows%20",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}