"id": "CVE-2021-44014",
"sourceIdentifier": "productcert@siemens.com",
"published": "2021-12-14T12:15:10.770",
"lastModified": "2023-02-21T18:35:00.857",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15057, ZDI-CAN-19081)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.5), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.5). El archivo Jt1001.dll contiene una vulnerabilidad de uso de memoria previamente liberada que podr\u00eda desencadenarse al analizar archivos JT especialmente dise\u00f1ados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15057)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-416"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-416"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "11.1.1.0",
"matchCriteriaId": "8E5FA782-E074-4406-ACA6-788DD24327C7"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.1.1.0",
"matchCriteriaId": "A46E8F39-E213-48F4-8355-E34118668B49"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.2.0.5",
"matchCriteriaId": "16503D23-333C-4282-B4FE-EF51ED89209A"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "se2023",
"matchCriteriaId": "F20768FD-EB6F-40EA-BDEA-17C9BA60A1E6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.2.0.5",
"matchCriteriaId": "6C1C132F-3514-40F7-B7F9-D4FD8C36029A"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}