"id": "CVE-2021-44017",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2021-12-14T12:15:10.870",
|
|
"lastModified": "2022-03-30T13:02:54.673",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The Image.dll is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted TIF files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15111)"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.5), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.5). El archivo Image.dll es vulnerable a una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado al analizar archivos TIF especialmente dise\u00f1ados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-15111)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.5,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.3
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.6,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": true
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "13.2.0.5",
|
|
"matchCriteriaId": "16503D23-333C-4282-B4FE-EF51ED89209A"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "13.2.0.5",
|
|
"matchCriteriaId": "6C1C132F-3514-40F7-B7F9-D4FD8C36029A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-011/",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
}
|
|
]
|
|
} |