René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

116 lines
3.8 KiB
JSON

{
"id": "CVE-2021-45732",
"sourceIdentifier": "vulnreport@tenable.com",
"published": "2021-12-30T22:15:10.063",
"lastModified": "2022-01-11T17:20:31.657",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Netgear Nighthawk R6700 version 1.0.4.120 makes use of a hardcoded credential. It does not appear that normal users are intended to be able to manipulate configuration backups due to the fact that they are encrypted/obfuscated. By extracting the configuration using readily available public tools, a user can reconfigure settings not intended to be manipulated, repackage the configuration, and restore a backup causing these settings to be changed."
},
{
"lang": "es",
"value": "Netgear Nighthawk R6700 versi\u00f3n 1.0.4.120, usa una credencial embebida. No parece que usuarios normales puedan manipular las copias de seguridad de la configuraci\u00f3n debido a que est\u00e1n cifradas/ofuscadas. Al extraer la configuraci\u00f3n usando herramientas p\u00fablicas f\u00e1cilmente disponibles, un usuario puede reconfigurar los ajustes que no est\u00e1n destinados a ser manipulados, volver a empaquetar la configuraci\u00f3n y restaurar una copia de seguridad causando que estos ajustes sean cambiados.\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6700_firmware:1.0.4.120:*:*:*:*:*:*:*",
"matchCriteriaId": "AA1C8A12-2DF8-4414-ACAF-9AC869331CE9"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2"
}
]
}
]
}
],
"references": [
{
"url": "https://www.tenable.com/security/research/tra-2021-57",
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory"
]
}
]
}