René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.9 KiB
JSON

{
"id": "CVE-2022-27241",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-04-12T09:15:15.060",
"lastModified": "2022-07-12T14:15:15.560",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.11), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). Applications built with an affected system publicly expose the internal project structure. This could allow an unauthenticated remote attacker to read confidential information."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en las aplicaciones de Mendix que utilizan Mendix 7 (Todas las versiones anteriores a la versi\u00f3n V7.23.31), las aplicaciones de Mendix que utilizan Mendix 8 (Todas las versiones anteriores a la versi\u00f3n V8.18.18), las aplicaciones de Mendix que utilizan Mendix 9 (Todas las versiones anteriores a la versi\u00f3n V9.11), las aplicaciones de Mendix que utilizan Mendix 9 (V9.6) (Todas las versiones anteriores a la versi\u00f3n V9.6.12). Las aplicaciones construidas con un sistema afectado exponen p\u00fablicamente la estructura interna del proyecto. Esto podr\u00eda permitir a un atacante remoto no autentificado leer informaci\u00f3n confidencial"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.0.0",
"versionEndExcluding": "9.11.0",
"matchCriteriaId": "DC850CB1-4E44-4D38-90E2-48CA73A979A4"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-414513.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}