mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-09-17 18:45:49 +00:00
109 lines
3.1 KiB
JSON
109 lines
3.1 KiB
JSON
{
|
|
"id": "CVE-2012-3011",
|
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
|
"published": "2012-09-25T11:07:46.110",
|
|
"lastModified": "2024-11-21T01:40:07.130",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Directory traversal vulnerability in the web server in Fultek WinTr Scada 4.0.5 and earlier allows remote attackers to read arbitrary files via a crafted request."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Vulnerabilidad de salto de directorio en el servidor web de Fultek Wintr Scada v4.0.5 y anteriores permite a atacantes remotos leer archivos de su elecci\u00f3n a trav\u00e9s de una petici\u00f3n hecha a mano.\r\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
|
|
"baseScore": 7.8,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fultek:wintr_scada:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "4.0.5",
|
|
"matchCriteriaId": "4540B12E-9E4E-436E-A46C-B1C29AA7D99D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fultek:wintr_scada:2.0.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "65A17BCD-251C-4BBB-A0D2-CB411D43588D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fultek:wintr_scada:2.5:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "729DDF64-B052-4EC7-969A-701E1CFD8942"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://secunia.com/advisories/50668",
|
|
"source": "ics-cert@hq.dhs.gov"
|
|
},
|
|
{
|
|
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-262-01.pdf",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://secunia.com/advisories/50668",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108"
|
|
},
|
|
{
|
|
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-262-01.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"US Government Resource"
|
|
]
|
|
}
|
|
]
|
|
} |