"id": "CVE-2012-6438",
|
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
|
"published": "2013-01-24T21:55:01.603",
|
|
"lastModified": "2024-11-21T01:46:07.650",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Buffer overflow in Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allows remote attackers to cause a denial of service (NIC crash and communication outage) via a malformed CIP packet."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Desbordamiento de b\u00fafer en Rockwell Automation EtherNet/IP; productos 1756-ENBT, 1756-EWEB, 1768-ENBT y m\u00f3dulos de comunicaci\u00f3n 1768-EWEB; CompactLogix L32E y L35E, 1788-ENBT adaptador FlexLogix; AENTR 1794-FLEX adaptador I/O EtherNet/IP; ControlLogix v18 y anteriores; CompactLogix v18 y anteriores; GuardLogix v18 y anteriores; SoftLogix v18 y anteriores; controladores CompactLogix v19 y anteriores; controladores SoftLogix v19 y anteriores; controladores ControlLogix v20 y anteriores, los controladores GuardLogix v20 y anteriores, y MicroLogix 1100 y 1400, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (ca\u00edda NIC y corte de la comunicaci\u00f3n) a trav\u00e9s de un paquete mal formado CIP."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
|
|
"baseScore": 7.8,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "COMPLETE"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:controllogix_controllers:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "20",
|
|
"matchCriteriaId": "37F4D4ED-1915-4155-9F0A-691771AA534B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:guardlogix_controllers:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "20",
|
|
"matchCriteriaId": "A2F8B5EE-C1BA-4CFB-B17F-C59BCDB41503"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "1100",
|
|
"matchCriteriaId": "DE554CCC-0A46-43D4-8D7D-44200BB7D314"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:micrologix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "1400",
|
|
"matchCriteriaId": "8D3B4218-4483-4FAE-9915-8937F40AED27"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:softlogix_controllers:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "19",
|
|
"matchCriteriaId": "FE7219A5-4759-4143-B89F-869D49CAAFF7"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:1756-enbt:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "330E9A05-C869-41B1-BB28-FD2A7C7ED0CE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:1756-eweb:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2AD7D5DB-4A49-421A-8C6C-B9E6DA0A499B"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:1768-enbt:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DD44B55C-BDD7-41CC-91A9-F31ED2FC69E2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:1768-eweb:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C91D5245-DED2-469C-A800-62109F8159C9"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:1794-aentr_flex_i\\/o_ethernet\\/ip_adapter:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0BD25E6B-6AE1-4B8C-A086-F5E152CAAA60"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "18",
|
|
"matchCriteriaId": "AA199887-E8F7-48EE-B1E0-9EF2E439DACE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_controllers:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "19",
|
|
"matchCriteriaId": "A763D845-B091-47A4-8A29-A1CD19C1E4F2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_l32e_controller:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "19B8ED27-2512-4A42-973C-99D300963046"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_l35e_controller:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7EFC590C-01C1-48D1-A5BE-0F70BE7F36B9"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:controllogix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "18",
|
|
"matchCriteriaId": "4FE24B9B-9F7D-4D8F-A674-F04FC9F9F8BC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:flexlogix_1788-enbt_adapter:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "887A3369-548C-42B0-82C5-92CB161D3B7A"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:guardlogix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "18",
|
|
"matchCriteriaId": "E98626DD-BC79-473E-B25F-92C9BA12F6DD"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:h:rockwellautomation:softlogix:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "18",
|
|
"matchCriteriaId": "D83AF504-2845-4022-BA8E-52F4FB773EA4"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"US Government Resource"
|
|
]
|
|
}
|
|
]
|
|
} |