"id": "CVE-2016-11038",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2020-04-07T14:15:13.497",
|
|
"lastModified": "2024-11-21T02:45:21.337",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An issue was discovered on Samsung mobile devices with software through 2016-04-05 (incorporating the Samsung Professional Audio SDK). The Jack audio service doesn't implement access control for shared memory, leading to arbitrary code execution or privilege escalation. The Samsung ID is SVE-2016-5953 (July 2016)."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se detect\u00f3 un problema en dispositivos m\u00f3viles Samsung con versiones de software hasta el 05-04-2019 (incorporando el Samsung Professional Audio SDK). El servicio de audio Jack no implementa el control de acceso para la memoria compartida, conllevando a una ejecuci\u00f3n de c\u00f3digo arbitraria o una escalada de privilegios. El ID de Samsung es SVE-2016-5953 (Julio de 2016)."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
|
|
"baseScore": 7.5,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_note_3:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "B148CE20-A498-4F1E-9C2D-C38F9F15292D"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_note_4:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "65AD2209-F89B-4CF2-BFA6-710D4E8A965A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_note_edge:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "8C58E9E1-08A0-4EA8-8EDE-CD7836A7289D"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_s5:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7060E1BD-9FFF-4D74-A2EE-20ABB447EA23"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_s6:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E9C84354-75A3-4E55-A2D0-C0783AF36B37"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:google:android:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F8B9FEC8-73B6-43B8-B24E-1F7C20D91D26"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:samsung:galaxy_s6_edge:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "64C60E27-871F-4B77-87A5-9F9F20DCA2D3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://security.samsungmobile.com/securityUpdate.smsb",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://security.samsungmobile.com/securityUpdate.smsb",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |