"id": "CVE-2017-6894",
|
|
"sourceIdentifier": "PSIRT-CNA@flexerasoftware.com",
|
|
"published": "2023-03-29T21:15:07.697",
|
|
"lastModified": "2025-02-18T18:15:08.657",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability exists in FlexNet Manager Suite releases 2015 R2 SP3 and earlier (including FlexNet Manager Platform 9.2 and earlier) that affects the inventory gathering components and can be exploited by local users to perform certain actions with elevated privileges on the local system."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-269"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-269"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "9.2",
|
|
"matchCriteriaId": "F96119EE-CA5E-4B16-9844-F2E8EEB811ED"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager_suite_2015:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7C5008FE-35BC-495B-BFEC-30FF5EF3D1EB"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager_suite_2015:r2:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5F70C306-6E8F-4385-A229-CA5370131593"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager_suite_2015:r2:sp1:*:*:*:*:*:*",
|
|
"matchCriteriaId": "DB32B277-C607-461B-BDF7-5F7D2CEA3C82"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager_suite_2015:r2:sp2:*:*:*:*:*:*",
|
|
"matchCriteriaId": "124DDE70-4D64-4F74-8826-764854AE6523"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:flexera:flexnet_manager_suite_2015:r2:sp3:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D604B146-7F70-4AE5-9FF8-4C71E3AD44A3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://community.flexera.com/t5/FlexNet-Manager-Knowledge-Base/A-vulnerability-exists-in-FlexNet-Manager-Suite-release-2015-R2/ta-p/1891",
|
|
"source": "PSIRT-CNA@flexerasoftware.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://community.flexera.com/t5/FlexNet-Manager-Knowledge-Base/A-vulnerability-exists-in-FlexNet-Manager-Suite-release-2015-R2/ta-p/1891",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |