"id": "CVE-2018-7778",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2018-07-03T14:29:01.210",
|
|
"lastModified": "2024-11-21T04:12:42.993",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "En las versiones anteriores a la v3.2.0-12_v1 de Schneider Electric Evlink Charging Station, la interfaz web tiene un problema que puede permitir que un atacante remoto obtenga privilegios administrativos sin autenticar correctamente a los usuarios remotos."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
|
|
"baseScore": 7.5,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "PARTIAL",
|
|
"availabilityImpact": "PARTIAL"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.4,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-306"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:evlink_charging_station_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.2.0-12_v1",
|
|
"matchCriteriaId": "0B2C5810-2436-4AE7-8B3E-5D28F91C098E"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:evlink_charging_station:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D7BA4983-91EA-4E08-865E-1F4B3CCF28F8"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |