mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-09-17 18:45:49 +00:00
185 lines
5.2 KiB
JSON
185 lines
5.2 KiB
JSON
{
|
|
"id": "CVE-2018-8840",
|
|
"sourceIdentifier": "ics-cert@hq.dhs.gov",
|
|
"published": "2018-04-18T20:29:00.920",
|
|
"lastModified": "2024-11-21T04:14:25.670",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Un atacante remoto podr\u00eda enviar un paquete cuidadosamente manipulado en InduSoft Web Studio, en versiones 8.1 y anteriores, y/o en InTouch Machine Edition 2017, en versiones 8.1 y anteriores, durante una acci\u00f3n relacionada con una etiqueta, alarma o evento como la lectura o escritura. Esto podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV30": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.0",
|
|
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
|
|
"baseScore": 10.0,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": true,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-121"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-119"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:indusoft:web_studio:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "8.1",
|
|
"matchCriteriaId": "A6BF553A-0EC5-4652-B8F7-FB27013DE9E3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:industrial-software:intouch_machine_edition_2017:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "8.1",
|
|
"matchCriteriaId": "2107AE24-C696-462B-8881-5F9E7FC90624"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/103949",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/research/tra-2018-07",
|
|
"source": "ics-cert@hq.dhs.gov",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000125/",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://www.securityfocus.com/bid/103949",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"VDB Entry"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-01",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Third Party Advisory",
|
|
"US Government Resource"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/research/tra-2018-07",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |