"id": "CVE-2023-2758",
|
|
"sourceIdentifier": "vulnreport@tenable.com",
|
|
"published": "2023-05-31T15:15:09.473",
|
|
"lastModified": "2024-11-21T07:59:14.063",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "vulnreport@tenable.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
|
|
"baseScore": 3.7,
|
|
"baseSeverity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "LOW"
|
|
},
|
|
"exploitabilityScore": 2.2,
|
|
"impactScore": 1.4
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
|
|
"baseScore": 5.3,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "LOW"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 1.4
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "vulnreport@tenable.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-799"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-Other"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.5.3",
|
|
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://jvn.jp/en/vu/JVNVU93372935/index.html",
|
|
"source": "vulnreport@tenable.com",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/research/tra-2023-21",
|
|
"source": "vulnreport@tenable.com",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://jvn.jp/en/vu/JVNVU93372935/index.html",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.tenable.com/security/research/tra-2023-21",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |