"id": "CVE-2024-31493",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2024-06-03T08:15:09.097",
"lastModified": "2024-06-03T14:46:24.250",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An improper removal of sensitive information before storage or transfer vulnerability [CWE-212] in FortiSOAR version 7.3.0, version 7.2.2 and below, version 7.0.3 and below may allow an authenticated low privileged user to read Connector passwords in plain-text via HTTP responses."
},
{
"lang": "es",
"value": "Una eliminaci\u00f3n inadecuada de informaci\u00f3n confidencial antes de la vulnerabilidad de almacenamiento o transferencia [CWE-212] en FortiSOAR versi\u00f3n 7.3.0, versi\u00f3n 7.2.2 e inferiores, versi\u00f3n 7.0.3 e inferiores puede permitir que un usuario autenticado con privilegios bajos lea las contrase\u00f1as del conector en formato texto plano a trav\u00e9s de respuestas HTTP."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "psirt@fortinet.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-212"
}
]
}
],
"references": [
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-24-052",
"source": "psirt@fortinet.com"
}
]
}