2023-08-10 16:00:36 +00:00

141 lines
4.4 KiB
JSON

{
"id": "CVE-2023-39181",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-08-08T10:15:17.080",
"lastModified": "2023-08-10T15:56:38.890",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "se2023",
"matchCriteriaId": "F20768FD-EB6F-40EA-BDEA-17C9BA60A1E6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:-:*:*:*:*:*:*",
"matchCriteriaId": "A8332862-1FB4-4824-9665-5A50184EB366"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "31441523-2923-4028-83E9-AAB998120A0E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "7986AB87-876E-4E47-AEEB-9936491AA535"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "734D353F-4DBF-4001-8BC2-0760BE40BE55"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack4:*:*:*:*:*:*",
"matchCriteriaId": "63FCD2EA-EFCF-4959-B5C2-801E870B37AE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack5:*:*:*:*:*:*",
"matchCriteriaId": "22949AFB-EF6F-4DF9-953B-5372686574B9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack6:*:*:*:*:*:*",
"matchCriteriaId": "8437DCAC-5CEC-4C52-80DE-91F785CB3F8E"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-811403.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}