"id": "CVE-2022-22297",
|
|
"sourceIdentifier": "psirt@fortinet.com",
|
|
"published": "2023-03-07T17:15:11.707",
|
|
"lastModified": "2024-11-21T06:46:35.323",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An incomplete filtering of one or more instances of special elements vulnerability [CWE-792] in the command line interpreter of FortiWeb version 6.4.0 through 6.4.1, FortiWeb version 6.3.0 through 6.3.17, FortiWeb all versions 6.2, FortiWeb all versions 6.1, FortiWeb all versions 6.0, FortiRecorder version 6.4.0 through 6.4.3, FortiRecorder all versions 6.0, FortiRecorder all versions 2.7 may allow an authenticated user to read arbitrary files via specially crafted command arguments."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "psirt@fortinet.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
|
|
"baseScore": 5.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 3.6
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
|
|
"baseScore": 5.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "psirt@fortinet.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-792"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-Other"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.0.0",
|
|
"versionEndIncluding": "6.0.8",
|
|
"matchCriteriaId": "DA69D7D6-9798-4E8C-983A-6632D665175C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.1.0",
|
|
"versionEndIncluding": "6.1.3",
|
|
"matchCriteriaId": "FAA01761-B03C-498C-8749-CD1289E37A08"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.2.0",
|
|
"versionEndIncluding": "6.2.7",
|
|
"matchCriteriaId": "2DBCF4EF-986E-4F59-8D6D-01AB0D783091"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.3.0",
|
|
"versionEndIncluding": "6.3.17",
|
|
"matchCriteriaId": "A846394C-F57F-432B-AEE0-F2FB576A55FA"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:fortinet:fortiweb:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.4.0",
|
|
"versionEndIncluding": "6.4.3",
|
|
"matchCriteriaId": "AF5ED7B3-39F3-49FD-82D9-72CAB2D68636"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:fortinet:fortirecorder_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2.7.0",
|
|
"versionEndIncluding": "2.7.7",
|
|
"matchCriteriaId": "1D08AB84-92D4-4E2E-A1C6-F6C9856E81B4"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:fortinet:fortirecorder_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.0.0",
|
|
"versionEndIncluding": "6.0.12",
|
|
"matchCriteriaId": "5CE6D7BA-0B60-42EF-BDE0-1E548794C145"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:fortinet:fortirecorder_firmware:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "6.4.0",
|
|
"versionEndIncluding": "6.4.3",
|
|
"matchCriteriaId": "E50EDA13-6FCE-4D96-9B3B-80D3B5814202"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://fortiguard.com/psirt/FG-IR-21-218",
|
|
"source": "psirt@fortinet.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://fortiguard.com/psirt/FG-IR-21-218",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |