"id": "CVE-2022-38743",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2022-10-17T21:15:10.343",
|
|
"lastModified": "2024-11-21T07:17:00.703",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Rockwell Automation FactoryTalk VantagePoint versiones 8.0, 8.10, 8.20, 8.30, 8.31, son susceptibles a una vulnerabilidad de control de acceso inapropiada. La cuenta de FactoryTalk VantagePoint SQL Server podr\u00eda permitir a un usuario malicioso con privilegios de s\u00f3lo lectura ejecutar sentencias SQL en la base de datos del back-end. Si es explotado con \u00e9xito, esto podr\u00eda permitir al atacante ejecutar c\u00f3digo arbitrario y conseguir acceso a datos restringidos"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-284"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-Other"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "CAD07421-BA29-47E8-B96B-424C35194F2F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5F68655B-5ED9-4B1C-9E7E-4374F5A31AFE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.20:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "272D6C41-9E30-4A70-BAD7-A94D8EE51167"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.30:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "43E695DF-8CB1-49AA-BFEC-18336C2FCF8D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.31:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "EA050720-1DC3-4B74-9AE4-5212D4A81938"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043",
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"tags": [
|
|
"Permissions Required",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Permissions Required",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |