2024-12-08 03:06:42 +00:00

215 lines
6.6 KiB
JSON

{
"id": "CVE-2023-46664",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2023-10-26T21:15:07.967",
"lastModified": "2024-11-21T08:29:00.930",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\n\n\n\n\n\n\n\n\n\n\n\n\nSielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.\n\n\n\n\n\n\n\n"
},
{
"lang": "es",
"value": "Sielco PolyEco1000 es afectada por una vulnerabilidad de control de acceso inadecuado cuando la aplicaci\u00f3n proporciona acceso directo a objetos bas\u00e1ndose en la entrada proporcionada por el usuario. Como resultado de esta vulnerabilidad, los atacantes pueden eludir la autorizaci\u00f3n y acceder a recursos detr\u00e1s de p\u00e1ginas protegidas."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco500_firmware:1.7.0:*:*:*:cpu:*:*:*",
"matchCriteriaId": "E64F96A4-542A-486E-AC9A-3EC1E68A6D1E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco500_firmware:10.16:*:*:*:fpga:*:*:*",
"matchCriteriaId": "E3A4049B-D0B2-4CB6-8B31-ECD3BF4FF384"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sielco:polyeco500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D7E931F0-5608-4F24-821B-3DB29972C077"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco300_firmware:2.0.0:*:*:*:cpu:*:*:*",
"matchCriteriaId": "BBA5260D-A7D3-4973-8106-E8C73F50A6CE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco300_firmware:2.0.2:*:*:*:cpu:*:*:*",
"matchCriteriaId": "F7CE9236-A970-49F0-A200-84BC3B77CECB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco300_firmware:10.19:*:*:*:fpga:*:*:*",
"matchCriteriaId": "D45CE1CD-FB47-4FFD-974E-B55B569A5850"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sielco:polyeco300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "05832105-6C9E-4850-A145-F3E241058CCA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:1.9.3:*:*:*:cpu:*:*:*",
"matchCriteriaId": "991B1AD8-671D-4EF9-901B-0834748258F5"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:1.9.4:*:*:*:cpu:*:*:*",
"matchCriteriaId": "FE961B31-1553-4457-8436-8F9662AA10CA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:2.0.6:*:*:*:cpu:*:*:*",
"matchCriteriaId": "0BF0380D-483C-4B14-BF42-AC1E9C79D2DE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sielco:polyeco1000_firmware:10.19:*:*:*:fpga:*:*:*",
"matchCriteriaId": "F0E5773E-8842-4FCB-80BD-266A237042E7"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sielco:polyeco1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01DB9D87-6F35-4171-AD59-9B90386F431E"
}
]
}
]
}
],
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-299-07",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}