2024-12-08 03:06:42 +00:00

72 lines
2.9 KiB
JSON

{
"id": "CVE-2024-0220",
"sourceIdentifier": "cybersecurity@ch.abb.com",
"published": "2024-02-22T11:15:08.840",
"lastModified": "2024-11-21T08:46:05.430",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."
},
{
"lang": "es",
"value": "B&R Automation Studio Upgrade Service y B&R Technology Guarding utilizan criptograf\u00eda insuficiente para la comunicaci\u00f3n con la actualizaci\u00f3n y los servidores de licencias. Un atacante basado en la red podr\u00eda aprovechar la vulnerabilidad para ejecutar c\u00f3digo arbitrario en los productos o rastrear datos confidenciales. Falta de cifrado de datos confidenciales, transmisi\u00f3n de texto plano de informaci\u00f3n confidencial, control inadecuado de la generaci\u00f3n de c\u00f3digo (\"inyecci\u00f3n de c\u00f3digo\"), vulnerabilidad de fuerza de cifrado inadecuada en B&R Industrial Automation B&R Automation Studio (m\u00f3dulos de servicio de actualizaci\u00f3n), B&R Industrial Automation Technology Guarding.Este problema afecta a B&R Automation Studio: <4,6; Protecci\u00f3n de tecnolog\u00eda: <1.4.0."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 6.0
}
]
},
"weaknesses": [
{
"source": "cybersecurity@ch.abb.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-94"
},
{
"lang": "en",
"value": "CWE-319"
},
{
"lang": "en",
"value": "CWE-1240"
}
]
}
],
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf",
"source": "cybersecurity@ch.abb.com"
},
{
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
]
}