"id": "CVE-2024-0568",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2024-02-14T17:15:11.440",
|
|
"lastModified": "2024-11-21T08:46:53.777",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nCWE-287: Improper Authentication vulnerability exists that could cause unauthorized tampering\nof device configuration over NFC communication.\n\n"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "CWE-287: Existe una vulnerabilidad de autenticaci\u00f3n incorrecta que podr\u00eda provocar una manipulaci\u00f3n no autorizada de la configuraci\u00f3n del dispositivo a trav\u00e9s de la comunicaci\u00f3n NFC."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:se:rmnf22tb30_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "8AD0EE30-4C33-49FC-ACAF-0954B6146663"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:se:rmnf22tb30:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E183566E-1734-4530-8919-066259D6FBF5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:se:renf22r2mmw_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "ABF12535-94D8-4D4A-81F9-55C37C59052D"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:se:renf22r2mmw:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7855741A-4D18-408A-A7EB-C37C1388ADA3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-02.pdf",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-02.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |