2025-01-09 17:04:14 +00:00

126 lines
3.9 KiB
JSON

{
"id": "CVE-2024-25964",
"sourceIdentifier": "security_alert@emc.com",
"published": "2024-03-25T09:15:09.477",
"lastModified": "2025-01-09T16:44:51.983",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerScale OneFS 9.5.0.x through 9.7.0.x contain a covert timing channel vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to denial of service."
},
{
"lang": "es",
"value": "Vulnerabilidad de inyecci\u00f3n SQL en el sistema CIGESv2, a trav\u00e9s de /ajaxServiciosAtencion.php, en el par\u00e1metro 'idServicio'. La explotaci\u00f3n de esta vulnerabilidad podr\u00eda permitir a un usuario remoto recuperar todos los datos almacenados en la base de datos enviando una consulta SQL especialmente manipulada."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "LOW"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-385"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"versionStartIncluding": "9.5.0.0",
"versionEndExcluding": "9.5.0.7",
"matchCriteriaId": "F071B492-8628-4AEE-8F7C-607414A47C58"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*",
"versionStartIncluding": "9.6.1",
"versionEndExcluding": "9.7.0.1",
"matchCriteriaId": "E9CD858A-BE31-4538-B700-60946A32CD60"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000222691/dsa-2024-062-security-update-for-dell-powerscale-onefs-for-proprietary-code-vulnerabilities",
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.dell.com/support/kbdoc/en-us/000222691/dsa-2024-062-security-update-for-dell-powerscale-onefs-for-proprietary-code-vulnerabilities",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}