2024-12-20 19:03:44 +00:00

112 lines
3.9 KiB
JSON

{
"id": "CVE-2024-8805",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"published": "2024-11-22T21:15:18.660",
"lastModified": "2024-12-20T18:05:47.173",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "BlueZ HID over GATT Profile Improper Access Control Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of BlueZ. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the implementation of the HID over GATT Profile. The issue results from the lack of authorization prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-25177."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo en el control de acceso inadecuado del perfil HID sobre GATT de BlueZ. Esta vulnerabilidad permite a los atacantes adyacentes a la red ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de BlueZ. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad. La falla espec\u00edfica existe dentro de la implementaci\u00f3n del perfil HID sobre GATT. El problema es el resultado de la falta de autorizaci\u00f3n antes de permitir el acceso a la funcionalidad. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del usuario actual. Era ZDI-CAN-25177."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:bluez:bluez:5.77:*:*:*:*:*:*:*",
"matchCriteriaId": "55E1D2F1-2073-4451-8D1A-A60DDD0E2ABD"
}
]
}
]
}
],
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1229/",
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
]
}
]
}